Hard-won, non-obvious findings from putting a hand-written Matter node next to the Aliro UWB reader on a DWM3001CDK (nRF52833 + DW3110, NCS v3.3.0 / Zephyr). The goal was a board that goes from factory to walk-up unlock and a working Home tile with nothing but the Home app — no build-time key, no donor ESP32, nothing typed in.

The sibling document for the other port is esp32-gotchas.md. This one is narrower and deeper: the nRF52833 has 128 KB of RAM, and almost every trap below is either that constraint or a consequence of writing the Matter node by hand rather than linking CHIP.

Code lives under firmware, the portable Matter node in modules/woz_matter, and the reader in modules/woz_aliro (shared byte-for-byte with the ESP32 port — see §9.2).

> Verification convention: VERIFIED = observed on this silicon; MEASURED = a > number read off the target, not estimated; PREDICTED = derived from source or spec > and never observed here, so a hazard to measure rather than a finding.

---

1. RAM is the binding constraint, and it bites as stack overflows

1.1 The budget, measured

MEASURED. Reader + hand-written Matter node + Thread MTD/SED, at the end of this work: 126,760 B of 131,072 B (96.7%), 4,312 B free. Flash was never close — 442 KB of 504 KB (85%).

127,352 B has been recorded as unrunnable on this board. That is an observation, not a spec, but treat it as a ceiling: builds above it have failed to come up. Every RAM change needs a boot check (§8.4), and the ECDH self-test line is the cheap proof the image is alive:

*** Booting nRF Connect SDK v3.3.0 ***
ECDH self-test: PASS (NIST CAVP P-256 CDH count 0)

1.2 Three different stacks overflowed, all from adding one feature

VERIFIED. Adding persistence to the Matter node produced three MPU stack-guard faults on three different threads, over a few hours. None was diagnosable from the symptom, and two presented as something else entirely:

StackMeasured peakWhat the default boughtSymptom
system work queue3,872 B4096 left 224 Bfault mid-unlock, right after SENT_AUTH0
ot_work_q (the Interaction Model)3,072 B3168 default left 96 Bpaired once, then halted at CommissioningComplete
z_main_stack4096, blown by a 1,642 B frameboard advertised, froze 4 s into boot
matter_wq_stack2,776 B of 4,096healthy— measuring it is what ruled it out

The lesson is not "these numbers": it is that a default is a starting point, not a size, and that two of the three were within a few hundred bytes of fitting. A margin that thin fails only when something else happens to run at the same moment, which is why identical firmware worked for weeks and then failed twice in an evening.

1.3 Read the paint; never estimate

VERIFIED. CONFIG_INIT_STACKS=y fills stacks with 0xAA and costs nothing at runtime. A debugger reads the high-water mark straight out of RAM, so no analyzer thread is needed:

# addresses from build-*/app/zephyr/zephyr.map
JLinkExe … -CommandFile <(printf 'savebin s.bin, 0x20015900, 0x1040\nq\n')
# skip the 64 B MPU guard at the low end, count the leading 0xAA run:
#   peak = (size - guard) - run

CONFIG_THREAD_ANALYZER_AUTO measures the same paint and costs a thread plus its stack — enabling it took an image to 96.6% RAM and past the unrunnable figure. Use the paint, not the analyzer, on this part.

Two traps when reading it:

  • The MPU guard occupies the first 64 B and is never painted. Counting 0xAA from

offset 0 reports "100% used" on a healthy stack.

  • Symbol addresses move with every BSS change. A stale address reads as garbage, and

a stale last_count (§8.3) reads as a hung board. Re-read from the map after every build.

1.4 Where the bytes went, and the cheap reclaims

MEASURED. Two changes cost far more than they looked:

  • Raising ALIRO_TRUST_MAX 4 → 8 grew ALIRO_PROV_BLOB_MAX 476 → 864 B and

struct aliro_trust_store 390 → 778 B. A function holding both had a 1,642 B frame, which went through the bottom of the 4 KB main stack. Fix: the blob is static, and the cap settled at 6.

  • A struct matter_im_read made static to describe one attribute costs ~264 B,

because it carries MATTER_IM_MAX_PATHS. On the stack instead, on a work queue with measured headroom.

General rule on this part: large single-use objects belong on a stack with known headroom, not in BSS — but only after that headroom has been measured.

---

2. Matter state must not be written from the OpenThread thread

VERIFIED. Matter datagrams arrive through the OpenThread UDP callback, so the entire Interaction Model — decrypt, decode, cluster command, response encode, framing — runs on ot_work_q. Two separate failures came from that:

1. An NVS write there overflows it. CommissioningComplete → store fabrics → NVS faulted after both fabrics were accepted, both CASE sessions established and the subscription primed. The pairing succeeded on the wire and failed anyway. 2. A write anywhere in a handshake stalls it. Storing at AddNOC wrote ~1.7 KB across several settings keys; an NVS sector erase on this part runs to tens of milliseconds. The commissioner retransmitted Sigma1 and the second fabric's CASE died with Sigma3 REJECTED (-6) ×5, then RemoveFabric.

Rule: persist at CommissioningComplete only, and submit it to the system work queue. Apple runs commissioning twice (once per administrator), so both fabrics are still captured. A fabric is worthless before commissioning completes anyway — if the commissioner gives up half way, the fail-safe is supposed to discard it.

Deferring also has to happen after the response has left: the InvokeResponse is still in the shared report buffer at that point, and building a second message there overwrites the reply with the report.

---

3. A subscription the node can actually serve needs four things

VERIFIED. "Matter Accessory / No Response", and a Home tile stuck spinning on Unlocking, were four independent bugs. Each looked like the whole problem on its own.

3.1 The priming report must fit the IPv6 MTU

MATTER_MAX_MESSAGE_LEN (1232) is the ceiling for the whole message — 1280 less the IPv6 and UDP headers — so the exchange headers (36) and the AEAD tag (16) come out of it, not on top. Spending all 1232 on the payload builds a datagram up to 52 bytes over the MTU.

Nothing logs. The framing succeeds, the send returns fine, and the datagram is simply never delivered, so the subscriber re-subscribes forever and the CASE table churns.

BLE hides this. BTP re-fragments, so the identical report crosses a commissioning session intact and only subscriptions carried over Thread fail — which presents as an accessory that works while pairing and dies immediately after. Tell it apart by which transport the established subscription sat on, not by whether one established at all.

3.2 The node must be able to initiate an exchange

Everything a responder-only node sends answers something. After the priming report the server has to speak unprompted, and a controller that gets no report calls the accessory unresponsive however healthy the session is.

The session role is unchanged, which makes this cheap: keys stay role-relative to CASE (still encrypt with r2i) and the message counter is per-session, not per-exchange. Only the exchange role differs — set I, use an id of your own, and do not write it back over the peer's live exchange id.

Two subtleties, both found by tests rather than by reading the code:

  • Never piggyback the peer's pending ack onto an exchange you just opened. An ack

names a counter within an exchange.

  • Do not clear ack_pending on that path. Clearing an ack that was never encoded

makes the peer retransmit a message already handled, and the exchange that owes the ack stalls.

3.3 Report on change

The tile reads LockState, not the InvokeResponse. A controller takes the SUCCESS and then waits for the attribute to be reported before the UI moves — so answering the command and stopping there is a lock that opens and a UI that spins forever.

3.4 Report on a timer, not only on change

Matter's contract is a report at least every max_interval whether or not anything changed (600 s is what Apple asks for here). Reporting only on change means a lock nobody touches for ten minutes stops existing.

One timer for all subscriptions, not one each: they carry the same attribute, the interval is a floor rather than a schedule, and six timers is not a reasonable thing to spend at 96.7% RAM. 120 s is deliberately early — a report is ~67 B on a link whose round trip measured 1.4 s, so being early is nearly free and being late is the entire failure. Stop re-arming when nothing is subscribed, so a node nobody watches is not waking its radio.

3.5 Bridge the reader's own state into LockState

VERIFIED. A walk-up unlock never touches the Door Lock cluster — it is the reader's own Aliro transaction — so the tile keeps showing whatever the last tile tap set. The Wallet animates unlocked while the app says locked, and the app is not wrong so much as uninformed.

Hook the point that sends the reader-status notification, because it carries both transitions (the grant that fires the animation and the walk-away relock). Do not use a credential-verdict callback: it fires on the unlock and never on the relock, so the tile would show a lock that opens and never closes.

---

4. Persistence, and what must not be persisted

4.1 Nothing Matter-side was persisted at all

VERIFIED. The fabric table was plain RAM, so every reset silently un-commissioned the node: it came back advertising commissionable, Thread never started because nothing replayed the dataset, and the controller showed an accessory that was simply gone. Every flash cost a full re-pair, which is also why iterating on this port was so expensive.

Persist the fabrics, the Thread dataset, the xPAN id and the ICAC slot. Then restore is not enough on its own: a restored identity is commissioned but not reachable until the dataset is handed to the stack and one SRP instance per fabric is registered. That pair is what commissioning does as a side effect; the boot path has no commissioner to trigger it.

4.2 One settings key per field, not one blob

A single record is ~1.7 KB and needs a buffer that size to build in. Saving each field straight out of the struct it already lives in costs no buffer at all — which matters on a part that has already taken stack-guard faults (§1.2).

4.3 A stored record implies commissioning_complete

VERIFIED. Not persisting it meant a restored node looked mid-commissioning, so the next commissioner to open a PASE session rolled back the fabrics that had just been restored — silently destroying a working pairing on the first failed connection after a reboot. Nothing writes a record before CommissioningComplete, so the flag is implied.

4.4 Never west flash --erase once the node has joined Thread

VERIFIED, and it costs up to 14 days. The SRP host name is the EUI-64 from factory FICR and is stable across an erase; the SRP client's key lives in OpenThread's settings and is not. SRP name ownership is first-come-first-served by key, so a new key for the same name is refused with OT_ERROR_DUPLICATED until the border router's key lease expires — default 14 days.

Symptom: Thread attaches and gets a routable address, SRP never registers, the commissioner cannot resolve the node, and the controller hangs forever on "Adding to Home".

Use the software clears instead (§7). They wipe everything a controller can see and leave OpenThread's settings alone.

4.5 An erase that cannot fail visibly

VERIFIED. Discarding every settings_delete() return behind (void) and logging "erased" unconditionally made a wipe that removed nothing indistinguishable from one that worked. Several hours were spent re-clearing a board that kept coming back with the same fabrics. Report each key's rc.

---

5. Advertising: one payload, one gate, and three ways to lose it

5.1 Only one payload fits a legacy advert

VERIFIED. Flags (3) + Matter service data (12) + Aliro service data (26) = 41 bytes of the 31 available. A second advertising set costs ~24.8 KB of RAM, which this part does not have. So the node advertises commissionable while it holds no fabric, and Aliro only once it does.

5.2 Restarting advertising from the disconnect callback fails

VERIFIED. bt_le_adv_start() returns -12 (-ENOMEM) when called from inside the disconnected callback — Zephyr has not released the connection object yet. Defer it to a work item and retry.

Worse than the failure was the silence: the advert logged only on success, so a failed restart left the reader invisible with nothing in the log but the "re-advertising" line before it. The board had unlocked once and then ignored every approach, while the Home tile kept working, because Matter runs over Thread and this is BLE. An advertising failure must never be quiet — it presents as dead hardware and points the investigation everywhere except at advertising.

5.3 Matter provisioning must refresh the advertisement

VERIFIED, and it hid for weeks. A phone resolves a reader by a dynamic tag derived from the GRK. The reader starts advertising long before SetAliroReaderConfig arrives, since the controller sends it as a post-commissioning operational command — so at start the GRK is the dev default's all zeros and only the bare 0xFFF2 UUID goes out.

Without an explicit refresh the board ends up provisioned, holding both credentials, reachable over Matter, tile working — and invisible to every walk-up.

A reboot hides it, because the boot path applies the stored GRK before it advertises at all, and every earlier test power-cycled after pairing. It only surfaced when a reboot happened before a pairing instead.

5.4 The advert gate must be re-run after a restore

The advert is chosen at BLE start, before stored fabrics are loaded. Without re-running it, a restored reader keeps advertising commissionable and never offers 0xFFF2 again — a node that unlocks until its first reboot and silently stops after it.

---

6. The trust store, and the issuer/endpoint key trap

6.1 A full store must evict, not refuse

VERIFIED. An Apple home installs two endpoint keys per pairing, they accumulate, and nothing removed them. With a cap of 4, the store filled on the second pairing and trust_add() answered a full store with a permanent refusal — so the key the phone actually presents could never be added, and pairing again only made it worse by adding more stale anchors. There is no recovery from that on a board with no console.

Observed as 13 consecutive walk-ups reaching device signature OK and then credential key NOT trusted. The two unlocks that appeared to work in the same session had gone through the expedited-fast path, which skips the trust check entirely — so the store had not matched a presented key once.

Evict a slot that has never completed a standard phase first (no Kpersistent means no phone ever authenticated with it), and only then the oldest.

6.2 Log the operands, not just the verdict

"not in trust store" names the comparison but not what was compared. The two candidate explanations — a credential that was never delivered, versus stale anchors crowding out the current one — are told apart only by the bytes. Printing the presented key beside every anchor turned an evening of guessing into one attempt.

6.3 Credential types, and a conclusion that was wrong twice

VERIFIED. SetCredential delivers type 6 (issuer key — correctly refused as an anchor) and type 7 (evictable endpoint key — stored). A pairing observed 3 calls: one type 6, two type 7.

This project recorded, then withdrew, then partly re-recorded a claim about these keys. The lesson that survived: an absence in a capture is evidence about the capture, not about the protocol. Captures that only ever showed type 6 were captures of pairings that never got far enough to send type 7 — the subscription bug (§3.1) was stopping them.

---

7. A failed pairing used to be a brick

VERIFIED, hit four times in one evening. A commissioning that installs a fabric and then times out leaves that fabric stored. The advert gate then offers Aliro 0xFFF2 instead of commissionable, so the controller can neither discover the node nor open a commissioning window on an accessory it has already forgotten. There is no way back.

Clearing it needs a debugger, a toolchain and the SWD header. A user has none of those, and the board looks dead.

The fix is a factory reset on SW2 held through reset: led0 blinks to confirm the hold registered, the reader identity, every trust anchor and the Matter fabrics are erased, and the boot continues commissionable. Held-through-reset rather than a long-press because it matches the provisioning console's existing idiom on the same button, needs no timer or thread at 96.7% RAM, and cannot fire during a walk-up.

It leaves OpenThread's settings alone — see §4.4 for the 14 days that erasing them costs.

If you are recovering a board without that button (older images), the equivalent is a one-boot clear flag, flashed once and then flashed away.

---

8. Debugging on this board

8.1 Poll the RTT ring with JLinkExe

VERIFIED, after two wrong turns.

  • JLinkGDBServer is wrong here: it disturbs the target enough to stop BLE, and

pairing then fails with the phone stuck on "connecting". Flowing RTT does not prove the core is running — that argument was made and was wrong.

  • JLinkRTTLogger only works in the foreground, so any keystroke kills the capture,

and it degrades to "RTT Control Block not found" on every invocation until the board's USB is replugged (nothing in software cures it).

  • JLinkExe never failed, including while the logger was broken, and is

non-interactive so it backgrounds cleanly.

Read WrOff/RdOff, savebin the ring, slice host-side for the wrap, then write RdOff back. Without the write-back the ring fills and NO_BLOCK_SKIP discards everything new — which looks exactly like a board that stopped logging.

Control block layout from the map: aUp[0] = _SEGGER_RTT + 24, then sName/pBuffer/SizeOfBuffer/WrOff/RdOff at +0/+4/+8/+12/+16.

8.2 Make a failed probe read loud

Silently continuing on a read error makes a broken J-Link indistinguishable from a quiet board. That ambiguity cost an hour.

8.3 Prove liveness independently

Read nrf_rtc_timer's last_count twice: it advances at 32,768 Hz iff the kernel runs. Re-read its address from the map after every build — a stale address returns a constant and reads as a hung board (this produced exactly one false "STILL HUNG").

For a fault, halt and read IPSR: 004 is MemManage. Compare the faulting SP against the stack regions in the map — an SP below a stack's base is that stack overflowing.

8.4 Prove reachability independently of the controller

dns-sd -B _matter._tcp local shows the operational services; dns-sd -Gv6 <host>.local gives the address; ping6 settles it. 0% loss while the controller reports "No Response" means the problem is not the device — that single check redirected the investigation more than once. Expect ~1.2–2.6 s RTT: it is a sleepy end device.

Note the mDNS records are cached by the border router, so stale instances from earlier failed pairings linger and are not evidence of anything.

---

9. Controller behaviour, and how to test against it

9.1 Every reboot costs ~10 minutes of controller sulk

VERIFIED, and it is not a bug to fix. Matter subscriptions are RAM on both sides. After a reset the controller keeps retransmitting into sessions the node lost — visible as encrypted for session 0xNNNN, which is not ours — and re-subscribes only when its own max_interval expires.

The node cannot force it. The exchange id needed to answer is inside ciphertext it has no key for. (An earlier claim here that a real node replies with a StatusReport was withdrawn; CHIP drops these too.)

The practical consequence dominates everything else in this document:

> Batch changes and test once. Flashing after each change resets the very state the > previous change needed to prove itself. Eight flashes in an hour demonstrated this the > expensive way — three separate fixes were built, flashed and left unproven because each > flash restarted the controller's timeout.

The other half of the same trap: the controller provisions late. Credentials have landed ~40 minutes after the pairing UI finished. A capture shorter than the thing being waited for will say it never happened.

9.2 modules/ is shared — run both suites

VERIFIED the hard way. A change under modules/woz_aliro was validated against the host suite only. The ESP32 suite — which is the only one that builds aliro_reader.c — had been broken by it two commits earlier and nobody noticed:

make test                  # host suite
./ports/esp32/test/run.sh  # host-compiled, no ESP-IDF, no hardware, seconds

When behaviour changes deliberately, update the stale assertions to the new behaviour rather than silencing them — a test asserting that a full trust store refuses is asserting the bug §6.1 exists.

9.3 A test proves nothing until you watch it fail

House rule, and it earned its keep repeatedly here: revert the fix, confirm the exact checks fail, restore. Two real bugs in §3.2 were found this way and not by reading.

9.4 Check exit codes, not output

A build reported success because the pipeline ended in tail, and the failure was invisible. Write to a file and test $?.

---

10. What is still open

  • Sigma3 REJECTED (-6) on a retransmitted Sigma1. Latent. An NVS stall made it easy

to hit (§2); removing the stall only hid it. Any commissioner that retransmits Sigma1 for any reason will meet it.

  • CONFIG_ALIRO_PROV_CLEAR_ON_BOOT does not apply. Set in prj.conf or an overlay

it still leaves # CONFIG_… is not set in .config, with no Kconfig warning, while a symbol added 22 lines later in the same file applies fine. The symbol has no depends on and no enclosing if/menu. Unexplained. Workaround: force the #if IS_ENABLED(...) to #if 1 for one boot, then revert.

  • SRP slot exhaustion when re-pairing without a rollback. Slots are released when

fabrics roll back, but a node that is genuinely commissioned and re-paired can still run out.

  • RAM at 96.7%. Any further work starts by measuring, not by adding.